Semaglutide

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
68
Confidence
82%
Panels
1/7
Purity (printed)
99.75%

Scored lower because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), 1 critical finding, and notable note: "Minimal documentation". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
Unknown
Sample date
2024-06-11
Issue date
2024-07-08

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 0 passed · 0 failed · 1 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Tested · result on file · core

    Reported purity percentage for the analyte.

    99.669%; 99.806%; 99.871%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Minimal documentation

    Report lacks detailed methodology, chromatograms, specifications, or pass/fail criteria. Very basic format compared to comprehensive COAs.

  • High purity reported

    Three measurements showing 99.669%, 99.806%, and 99.871% purity (average ~99.75%). This is within normal range for research-grade peptides.

  • Batch/lot number missing

    The batch field explicitly states 'Unknown', which is highly irregular for a legitimate COA. Batch traceability is essential for quality control.

  • No identity confirmation

    No identity testing method (MS, NMR, etc.) is documented. Only purity values are provided, with no confirmation that the compound is actually Semaglutide.

  • Limited testing scope

    This report only covers purity assessment. No identity, heavy metals, microbial, endotoxin, sterility, or residual solvent testing is included. This is a purity-only report.

  • Verification system provided

    Janoshik provides a verification URL (www.janoshik.com/verify/) with unique key Y8GCBEX7BNHS for authentication. Lab is known in the peptide testing community.

  • Dates are consistent

    Testing ordered 06 JUN 2024, sample received 11 JUN 2024, analysis conducted 08 JUL 2024. Timeline is logical and all dates are in the past relative to 2026-09-05.

Timing & next steps

Practical follow-ups based on document age and gaps.

  • coa age

    This COA was issued over a year ago (789 days) — consider whether a retest is warranted for this batch.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.