Retatrutide
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 2/7
- Purity (printed)
- 99.38%
Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- R-1001
- Identity method
- LC-MS/MS
- Sample date
- 2026-07-15
- Issue date
- 2026-07-18
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Retatrutide confirmed via LC-MS/MS precursor [M+5H]5+ 947.90 Da with quantifier/qualifier transitions
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.38%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High chromatographic purity
99.38% purity exceeds specification of ≥98%, which is normal and expected for research-grade peptides
Comprehensive identity confirmation
LC-MS/MS with precursor ion and multiple MRM transitions (quantifier 947.9›136.1, qualifier 947.9›110.1) provides robust identity verification
Clear lot identification
Lot number R-1001 clearly stated with sample ID RET-094 and report number COA-2026-SC-00309
Appropriate timeline
Sample received 07/15/2026, analyzed and reported 07/18/2026 - reasonable 3-day turnaround
Professional lab presentation
SideChain Analytics with detailed methodology, equipment specifications (Agilent 1290 Infinity II + 6495 QQQ), and verification QR code
Limited testing scope
This report covers identity and purity only. No heavy metals, microbial, endotoxin, sterility, or residual solvent/water testing included. This is common for basic purity/identity reports but users should verify if additional safety panels exist separately
Professional document structure
Well-organized with clear sections, sample photograph, chromatogram, appropriate disclaimers for research use only, and verification information
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.