Public COA audit

BPC-157 · Thymosin Beta-4

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
2/7
Purity (printed)
98.757%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 4 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
BPTB2b-12152025-J
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry
Issue date
2026-01-09

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    BPC-157/Thymosin Beta-4 confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    98.757%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    HPLC purity of 98.757% is excellent for a research peptide blend and is within normal range for quality peptides.

  • Identity confirmed by MS

    Mass spectrometry data shows expected molecular ions for both BPC-157 and TB4 components with appropriate charge states.

  • Lot number present

    Batch lot BPTB2b-12152025-J is clearly documented.

  • Missing received date clarity

    Received date shows 01/08/2026 and reported date 1/9/2026. While these are valid dates (before 2026-09-05), the one-day turnaround is unusually fast for comprehensive HPLC-MS analysis.

  • Lab verification unclear

    Freedom Diagnostics website (FreedomDiagnosticsTesting.com) and contact email ([email protected]) should be independently verified. The lab claims USA operation but provides limited accreditation information.

  • Limited testing scope

    This COA only covers identity and purity testing. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing is included. This is common for basic purity reports but limits safety assessment.

  • Professional presentation

    Document includes chromatogram, mass spectrum, product photos, and clear data presentation consistent with legitimate analytical reports.

  • Signature verification needed

    Document is signed by 'Stephen Schmidt, Principal Chemist' but signature authenticity cannot be verified from image alone.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.