Public COA audit
BPC-157 · Thymosin Beta-4
Audited July 28, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 85%
- Panels
- 2/7
- Purity (printed)
- 99.111%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- BPFTB20-12152025-J
- Identity method
- HPLC with UV Detection Coupled with Mass Spectrometry
- Issue date
- 2026-01-15
7-panel checklist
Standard peptide COA panels PeptIQ checks for on each document.
Identity
Compound identity confirmed (e.g. HPLC, mass spec).
BPC-157/Thymosin Beta-4
Result: pass
Purity
Reported purity percentage for the analyte.
99.111%
Result: pass
Heavy metals
Lead, arsenic, cadmium, mercury, or similar limits.
Microbial
Bioburden / microbial limits testing.
Endotoxin
LAL or chromogenic endotoxin assay.
Sterility
Sterility testing where applicable.
Residual solvent / water
Residual solvents or water content limits.
Findings
Evidence-linked observations from this audit.
High Purity Result
Purity of 99.111% is excellent for peptide compounds and consistent with quality manufacturing.
Identity Confirmed
Mass spectrometry data shows expected molecular ions for BPC-157 and TB-4 components with clear chromatographic separation.
Future Date Anomaly
Reported date is 1/15/2026, which is in the future. This is either a typo, mislabeling, or indicates the document may not be authentic as presented.
Batch Number Present
Lot number BPFTB20-12152025-J is clearly stated and follows a logical format.
Lab Verification Needed
Freedom Diagnostics is listed with website FreedomDiagnosticsTesting.com. Independent verification of this lab's accreditation and existence is recommended.
Limited Testing Scope
Only identity and purity testing performed. No heavy metals, microbial, endotoxin, sterility, or solvent testing. This is common for research-grade peptides but limits safety assurance.
Professional Presentation
Document has professional layout with clear tables, chromatograms, mass spec data, and product photo. Formatting is consistent with legitimate COA standards.
Received vs Reported Date Gap
Received date 1/13/2026 and reported date 1/15/2026 show only 2-day turnaround, which is fast but plausible for HPLC-MS analysis.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.