Public COA audit

BPC-157 · Thymosin Beta-4

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
88%
Panels
2/7
Purity (printed)
99.44%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 3 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
BPCTB410082025-04
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry (LCMS/MS)
Sample date
2025-10-10
Issue date
2025-10-12

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    BPC-157/Thymosin Beta-4 confirmed by mass spectrometry with peaks at m/z 710.33 [M+2H]2+, 991.43 [M+5H]5+, 1241.33 [M+4H]4+, 1419.38 [M+H]+

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.44%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.44% purity by HPLC is within normal range for research-grade peptides and is supported by clean chromatogram showing two distinct peaks for the two-peptide blend.

  • Mass spectrometry confirmation

    Mass spec data shows expected molecular ion peaks for both BPC-157 and TB-4/Thymosin Beta-4, with multiple charge states visible (M+H, M+2H, M+4H, M+5H), consistent with authentic peptide identification.

  • Lot number present

    Batch lot BPCTB410082025-04 is clearly stated and includes date encoding consistent with 2025 production.

  • Dates are valid

    Received 2025-10-10, reported 2025-10-12 (2-day turnaround). Both dates are before the current date of 2026-09-05 and represent reasonable testing timeline.

  • Limited lab verification information

    Freedom Diagnostics provides a website (FreedomDiagnosticsTesting.com) and email ([email protected]) but no physical address, accreditation information (ISO, GMP, etc.), or independent third-party verification. The lab claims to be 'Proudly Owned and Operated in the USA' but provides minimal credentials.

  • Limited testing scope

    This COA only covers identity and purity testing. No heavy metals, microbial, endotoxin, sterility, or residual solvent/water testing is included. This is a purity/identity-scoped report only and does not represent comprehensive safety testing.

  • Professional presentation

    Document includes chromatogram, mass spectrum, product photos, accession number, search code for verification, and signature of Principal Chemist Stephen Schmidt. Layout is clean and organized.

  • Research use disclaimer

    Document explicitly states peptides are 'intended for research use only and are not approved for human or veterinary use, diagnostic, therapeutic, or clinical applications.' Standard disclaimer but worth noting for end-use context.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.