Public COA audit

GLP-3

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
88%
Panels
5/7
Purity (printed)
99.8%

Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-3XAG30-2607-GREEN
Identity method
HPLC-UV/VIS
Issue date
2026-08-06

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Pass - Matches Ref. Standard

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    >99.80%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    All ND (As, Cd, Pb, Hg)

  • Microbial

    Tested · passed

    Bioburden / microbial limits testing.

    <10 CFU/mL aerobic, <10 CFU/mL yeast/mold

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    <5.00 EU/mg

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    HPLC purity >99.80% with consistent triplicate measurements (29.55, 29.19, 29.24 mg). Chromatogram shows clean single peak with minimal impurities.

  • Identity confirmed

    HPLC-UV/VIS identity test passed, matches reference standard.

  • Comprehensive testing suite

    Five major panels present: identity, purity, endotoxin (LAL), heavy metals (ICP-MS), and microbial (bioburden USP <61>). All panels passed.

  • A2LA accredited laboratory

    Vanguard Laboratory references A2LA Certificate #6377.01.01 for accredited tests. ISO 17025:2017 accreditation seal visible on page 1.

  • Date Released: 2026-08-06

    Issue date is 2026-08-06, which is within acceptable range (before today's date of 2026-09-05).

  • Lot number present

    Lot Number: CR-3XAG30-2607-GREEN. Laboratory ID: V260730-20 002.

  • Professional presentation

    Two-page report with clear tables, chromatogram, sample photo, signatures from Laboratory Director and Operations Manager, and standard disclaimers about sample representativeness.

  • Sterility and residual solvent panels absent

    No USP <71> sterility test or residual solvent/water content analysis present. This is common for non-sterile research-grade peptides but worth noting for completeness.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.