Public COA audit

VIP

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
1/7

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), 3 soft concerns, and notable note: "Endotoxin-only report". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
Yellow Cap
Issue date
2025-07-29

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    <5.00 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin-only report

    This COA is scoped exclusively to bacterial endotoxin testing (USP <85>). It does not include identity, purity, heavy metals, microbial, sterility, or residual solvent panels. This is a legitimate split-report format where endotoxin testing is performed separately from purity/identity testing.

  • No purity data

    No HPLC or other purity measurement is present in this document. This appears to be an endotoxin-specific report for lot Yellow Cap.

  • No identity confirmation

    No mass spectrometry, amino acid analysis, or other identity verification is included in this endotoxin-focused report.

  • Batch identifier present

    Client SID 'Yellow Cap' serves as the lot/batch identifier. Sample ID SPL-1446 is the lab's internal tracking number.

  • Lab information complete

    TrustPointe Analytics LLC is identified with full address (Dorr, MI), contact information, and verification URL (TrustPointeLIMS.com with key JSAQOXN1F205). Lab appears to be a legitimate third-party testing facility.

  • Endotoxin panel complete

    USP <85> bacterial endotoxin test shows <5.00 EU/mL with acceptable spike recovery (91%) and CV values (0.0% sample, 2.0% spike). Result passes the stated USP limit of 5 EU/kg/hr.

  • Professional presentation

    Document includes QR code for verification, dual signatures (Ashlee Lust, President; Joshua Lust, Managing Director), and standard COA formatting consistent with a legitimate analytical lab report.

Timing & next steps

Practical follow-ups based on document age and gaps.

  • coa age

    This COA was issued over a year ago (403 days) — consider whether a retest is warranted for this batch.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.