Public COA audit

BPC-157 · TB-500

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
88%
Panels
1/7

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), 2 soft concerns, and notable note: "Endotoxin testing present". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
BB202604
Issue date
2026-03-26

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    <5.05 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin testing present

    USP <85> bacterial endotoxin test performed with result <5.05 EU/mL, passing USP limit of 5 EU/kg/hr. Sample CV 0.5%, Spike CV 1.7%, Spike Recovery 109% all within acceptable ranges.

  • Limited scope report

    This COA is endotoxin-scoped only (note '-ENDO' suffix in sample name). No purity, identity, heavy metals, microbial, sterility, or residual solvent panels are present on this document. This appears to be a split report for lot BB202604; purity/identity testing may exist in a separate file.

  • Established testing laboratory

    TrustPointe Analytics LLC is a known third-party analytical testing laboratory in Dorr, MI with verifiable contact information and online verification system.

  • Batch number present

    Client SID BB202604 clearly documented.

  • No sample collection date

    Published date is 2026-03-26, but no sample collection or receipt date is documented on this report.

  • Professional formatting

    Document includes QR code verification, dual signatures (President and Managing Director), proper USP method citation, and quality control metrics (CV%, spike recovery).

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.