Public COA audit

TB-500

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
2/7
Purity (printed)
99.86%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 3 soft concerns, and notable note: "High purity across three vials". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
TB202601
Identity method
HPLC retention time and spectral match
Issue date
2026-01-14

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    RT match 1.00, Spectral match 1000

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.823%, 99.772%, 99.986%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity across three vials

    Three vials tested with purity values of 99.823%, 99.772%, and 99.986%. High purity is normal for research peptides and not a red flag by itself.

  • Identity confirmed by dual methods

    TB-500 identity verified by both retention time (RT) and spectral matching across all three samples.

  • Batch/lot number present

    Client SID TB202601 clearly documented.

  • Sample date not specified

    COA shows publication date (2026-01-14) but does not explicitly state when the sample was received or tested.

  • Lab information complete

    TrustPointe Analytics LLC with full address, contact information, and verification URL provided.

  • Limited testing scope - purity/identity only

    This COA covers purity and identity testing only. No heavy metals, microbial, endotoxin, sterility, or residual solvent/water testing is included in this report. This may be a purity-scoped report; the vendor may have separate reports for other panels.

  • Professional formatting with signatures

    Document includes QR code for verification, dual signatures (Ashlee Lust, President; Joshua Lust, Managing Director), and photo attachment of tested vials.

  • Assay values exceed label claim

    All three vials show assay values (10.896 mg, 10.487 mg, 10.623 mg) exceeding the 10mg label claim. While this can occur with overfill, it warrants verification that the vendor intended this or if there's a measurement/labeling discrepancy.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.