Public COA audit

Sermorelin

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
88%
Panels
1/7

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), 2 soft concerns, and notable note: "Endotoxin-only report". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
SM20250723
Sample date
2025-07-23
Issue date
2025-08-20

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    <5.00 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin-only report

    This COA is scoped specifically to endotoxin testing (USP <85>). It does not include purity, identity, heavy metals, microbial, sterility, or residual solvent panels. The client sample ID suffix 'ENDO' and the sample name '10mg, 1 vial ENDO' indicate this is an endotoxin-specific report, likely part of a split testing arrangement where other panels may be documented separately.

  • Verification URL provided

    Document includes verification URL (TrustPointeLIMS.com) and verification key (QWVBZBBMEBA5) for third-party validation.

  • Dates within normal range

    Sample date 2025-07-23 and issue date 2025-08-20 are both on or before the current date (2026-09-05) and show reasonable turnaround time (28 days).

  • Batch/lot number present

    Client SID SM20250723 provided, consistent with date-based lot numbering.

  • Professional presentation

    Document includes lab branding, QR code, dual signatures (President and Managing Director), contact information, and proper USP method citation.

  • Quality control metrics included

    Endotoxin testing includes sample CV (0.0%), spike CV (3.1%), and spike recovery (80%), demonstrating proper quality control. However, spike recovery at 80% is at the lower acceptable limit (typical range 80-120%).

Timing & next steps

Practical follow-ups based on document age and gaps.

  • coa age

    This COA was issued over a year ago (381 days) — consider whether a retest is warranted for this batch.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.