Public COA audit
Semax
Audited September 5, 2026
Missing panels or key metadata — not enough evidence to treat this as a full certificate.
- Legitimacy
- 45
- Confidence
- 85%
- Panels
- 1/7
Scored poorly because the file is incomplete or not a full COA, limited panel coverage (1/7), 2 critical findings, and notable note: "No purity testing". To improve: upload the full certificate (or the matching sibling purity/endotoxin report) and include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- SX202603
- Issue date
- 2026-05-05
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
1 of 7 present · 0 passed · 0 failed · 1 reported · 6 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Not on this certificate file · core
Compound identity confirmed (e.g. HPLC, mass spec).
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Purity
Not on this certificate file · core
Reported purity percentage for the analyte.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Heavy metals
Tested · result on file
Lead, arsenic, cadmium, mercury, or similar limits.
All Class 1 metals below detection limits; Class 2a/2b/3 metals detected at trace levels
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
No purity testing
This COA contains only heavy metals testing. No HPLC, MS, or other purity/identity analysis is present.
No identity confirmation
No mass spectrometry, NMR, amino acid analysis, or other identity verification method is documented.
Heavy metals only report
This appears to be a specialized heavy metals testing report only. The sample name includes 'HM' suffix suggesting this is a split report focused on elemental analysis. Purity, identity, endotoxin, microbial, and sterility testing are not included in this document.
No pass/fail criteria stated
Heavy metals results are reported as quantitative values but no acceptance limits or pass/fail determinations are provided.
Issue date valid
Published date 2026-05-05 is before current date 2026-09-05.
Lab information present
TrustPointe Analytics LLC with full contact details, verification URL, and QR code provided.
Batch/lot documented
Client SID SX202603 and internal Sample ID SPL-3611 both present.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.