Public COA audit

Semaglutide

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
88%
Panels
2/7
Purity (printed)
99.7%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
SM202601
Identity method
HPLC retention time and spectral match
Issue date
2026-01-10

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    RT match 1.00, Spectral match 1000

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.536-99.824%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity HPLC results

    Three vials tested with purity 99.536%, 99.731%, and 99.824% by HPLC method TM-1002. System suitability 0.9% RSD indicates good analytical precision.

  • Identity confirmed by dual methods

    Retention time match (1.00) and spectral match (1000) for all three samples, with coelution control passing (999-1000).

  • Clear batch identification

    Client SID SM202601 with three distinct sample IDs (SPL-2772, SPL-2772-S01, SPL-2772-S02) for triplicate testing.

  • Publication date provided

    Report published 2026-01-10 at 07:01. No sample receipt or testing dates explicitly stated.

  • Laboratory identification and verification

    TrustPointe Analytics LLC, Dorr MI, with verification URL TrustPointeLIMS.com and key 6HAF6DL59FTL. Contact information and dual signatures (President and Managing Director) present.

  • Limited testing scope - purity/identity only

    This COA covers purity and identity testing only. No endotoxin, heavy metals, microbial, sterility, or residual solvent/water testing included in this report. This is a purity/identity-scoped report and does not indicate whether additional safety panels were performed separately.

  • Professional presentation with photo attachment

    Clean formatting with QR code, dual signatures, and photo attachment of the three vials tested (page 2).

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.