Public COA audit
Retatrutide
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 83%
- Panels
- 2/7
- Purity (printed)
- 99.63%
Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 3 soft concerns, and notable note: "High HPLC purity across three vials". To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- RT202602
- Identity method
- HPLC retention time and spectral match (TM-1004)
- Issue date
- 2026-01-13
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
RT match 0.98-0.99, Spectral match 1000, Coelution 1000
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.610-99.669%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High HPLC purity across three vials
Purity values 99.610-99.669% with consistent assay results (26.090-26.978 mg) across three tested vials. System suitability 0.9 %RSD indicates good analytical precision.
Dual identity confirmation
Identity confirmed by both retention time (0.98-0.99) and spectral match (1000 score), with coelution check (1000) indicating no interference.
Client batch number present
Client SID RT202602 clearly documented.
Issue date documented
Published 2026-01-13, which is before the current date (2026-09-05) and therefore valid.
Lab identification and verification system
TrustPointe Analytics LLC with full contact information, verification URL (TrustPointeLIMS.com), and unique verification key (YGEUE3G233N2). Dual signatures from President and Managing Director.
Limited testing scope - purity/identity only
This COA covers only purity and identity testing (TM-1004 method). No heavy metals, microbial, endotoxin, sterility, or residual solvent/water testing is included in this report. This is a purity/identity-scoped report and does not indicate whether the vendor conducted additional testing in separate reports.
No sample receipt or collection date
Only the publication date is provided; no sample receipt date or collection date is documented.
Attachment reference without chromatogram
Page 2 references an attachment (SPL-2787.png) showing vials, but no HPLC chromatogram is included in this PDF to support the purity claims.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.