Public COA audit

Retatrutide

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
88%
Panels
2/7
Purity (printed)
98.815%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
RP20251001
Identity method
HPLC with retention time (RT) and spectral matching
Issue date
2025-10-14

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    RT match 1.00, Spectral match 1000

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    98.815% (adjusted 99.918% omitting glycine)

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity with transparent impurity disclosure

    Purity 98.815% reported; lab transparently notes glycine impurity (1.109-1.144%) and provides adjusted purity of 99.918%. This level of detail and transparency is consistent with legitimate analytical practice.

  • Dual identity confirmation

    Identity confirmed by both retention time (RT) and spectral matching (UV spectrum), with excellent match scores (1.00 RT, 1000 spectral).

  • Batch number present

    Client SID RP20251001 clearly stated.

  • Issue date within valid range

    Published 2025-10-14, which is before the current date of 2026-09-05.

  • Lab information complete with verification

    TrustPointe Analytics LLC with full address, contact info, verification URL (TrustPointeLIMS.com), and unique verification key (7B3AONHD3E94). Includes signatures from President and Managing Director.

  • Limited testing scope - purity/identity only

    This COA covers purity and identity testing only. No heavy metals, microbial, endotoxin, sterility, or residual solvent panels are present in this report. This is common for basic analytical COAs but users should verify if additional safety testing exists separately.

  • Professional presentation

    Well-formatted document with clear tables, QR code for verification, professional branding, and photo attachment of tested samples.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.