Public COA audit

KPV

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
2/7
Purity (printed)
99.36%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 3 soft concerns, and notable note: "High purity across all vials". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
KV202606
Identity method
HPLC retention time and spectral match
Issue date
2026-06-12

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    RT=1.00, Spectral=1000

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.344-99.387%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity across all vials

    Five vials tested with purity ranging 99.344-99.387%, consistent and within normal range for research peptides

  • Identity confirmed by dual methods

    Both retention time (RT=1.00) and spectral match (1000) confirm KPV identity across all samples

  • Batch number present

    Client SID KV202606 clearly stated

  • No sample receipt/collection date

    Published date 2026-06-12 is present but no sample receipt or collection date documented

  • Lab contact information complete

    TrustPointe Analytics LLC with full address, phone, email, and verification URL provided

  • Limited testing scope - purity/identity only

    This COA covers purity and identity testing only. No endotoxin, heavy metals, microbial, sterility, or residual solvent testing shown on this report. This may be a split report (purity-focused) or the vendor may not have ordered comprehensive testing.

  • Professional presentation with photo attachment

    Clean layout, dual signatures (President and Managing Director), QR code for verification, and photo of tested vials included

  • Unusual numeric codes for identity fields

    ID by Spectral and Coelution Control show '1000' values without units or clear pass/fail criteria explanation, though likely internal scoring system

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.