Public COA audit

GHK-Cu

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
88
Confidence
87%
Panels
2/7
Purity (printed)
99.7%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CU202605
Identity method
HPLC with retention time and spectral matching
Issue date
2026-05-13

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    RT match 1.00-1.01, Spectral match 1000

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.611-99.752%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Not on this COA · core

    LAL or chromogenic endotoxin assay.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity across all samples

    Five vials tested with purity ranging 99.611-99.752%, consistent with high-quality peptide synthesis

  • Multiple identity confirmations

    Identity confirmed via retention time matching (1.00-1.01) and spectral analysis (1000 match score), plus coelution control and system suitability checks

  • Clear batch identification

    Client SID CU202605 with internal sample IDs SPL-3752 through SPL-3752-S04

  • No sample collection date

    Published date 2026-05-13 is present but no explicit sample receipt or collection date documented

  • Verifiable laboratory

    TrustPointe Analytics LLC with physical address in Dorr, MI, verification URL, and QR code provided (Key=J4CKPF8K3KW9)

  • Limited testing scope

    Only identity and purity panels performed; no heavy metals, microbial, endotoxin, sterility, or residual solvent testing documented

  • Professional presentation

    Well-formatted report with signatures from President and Managing Director, includes photo attachment of actual vials

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.