Public COA audit
Ipamorelin · CJC-1295 (No DAC)
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 88%
- Panels
- 2/7
- Purity (printed)
- 99.93%
Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- CJIP202605
- Identity method
- HPLC with retention time (RT) and spectral matching
- Issue date
- 2026-05-14
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID by RT: 1.00, ID by Spectral: 1000 (both compounds)
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.929-99.938% across 5 vials
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity blend
Blend purity 99.929-99.938% across 5 vials with tight consistency. This is normal for research-grade peptides and not a red flag.
Dual-compound identity confirmed
Both Ipamorelin and CJC-1295 (No DAC) confirmed by retention time (1.00) and spectral matching (1000) across all 5 vials.
Quantitative assay results
Ipamorelin: 9.379-9.573 mg per vial (target 10mg). CJC-1295: 10.065-10.459 mg per vial (target 10mg). Reasonable variance for peptide reconstitution.
Batch/lot number present
Client SID: CJIP202605. Lab sample IDs: SPL-3789 (parent) with sub-samples S01-S04.
Issue date present and valid
Published 2026-05-14 21:50. This is before the authoritative current date (2026-09-05) and is valid.
Lab identification and verification
TrustPointe Analytics LLC, Dorr MI. Verification URL provided (TrustPointeLIMS.com) with key FXJFWJRK8QNQ. Contact info and physical address present.
Purity/identity-scoped report
This COA covers purity and identity testing only. No heavy metals, microbial, endotoxin, sterility, or residual solvent panels are present in this document. This is common for split testing where additional panels may be in separate reports.
Professional formatting with signatures
Document includes approval signatures (Ashlee Lust, President; Joshua Lust, Managing Director), QR code, and photo attachment of tested vials.
Sample date not stated
No explicit sample receipt or collection date is printed on the COA, only the publication/issue date.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.