Public COA audit

Ipamorelin · CJC-1295 (no DAC)

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
2/7
Purity (printed)
99.939%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 2 soft concerns, and notable note: "High purity confirmed across all vials". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CJIP202602
Identity method
HPLC with retention time (RT) and spectral matching
Issue date
2026-02-27

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    RT match 1.00, Spectral match 1000 for both compounds

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.908-99.939%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed across all vials

    Blend purity ranges 99.908-99.939% across four vials tested, with consistent results. This is normal for research-grade peptides.

  • Dual identity confirmation

    Both Ipamorelin and CJC-1295 confirmed by retention time (1.00) and spectral matching (1000) across all samples.

  • Quantitative assay results

    Ipamorelin: 9.205-9.417 mg per vial (target 10mg). CJC-1295: 10.061-10.209 mg per vial (target 10mg). Both within reasonable variance.

  • Verification system provided

    Document includes QR code and verification URL (TrustPointeLIMS.com) with key UQJA23MYE4VT for independent verification.

  • No sample receipt/collection date

    COA shows publication date (2026-02-27) but does not specify when samples were received or testing was performed.

  • Limited testing scope - purity/identity only

    This COA covers purity and identity testing only. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing is included in this report. This may be a split report (purity-focused), or the vendor may not have commissioned comprehensive testing.

  • Professional presentation with signatures

    Document includes dual approval signatures (President and Managing Director), sample photo attachment, and professional formatting consistent with legitimate lab reports.

  • Complete lab contact information

    Full address (1743 142nd Ave Suite 4, Dorr, MI 49323), phone (616-359-9023), email, and website provided.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.