Public COA audit

Cagrilintide

Audited September 5, 2026

Incomplete documentation

Missing panels or key metadata — not enough evidence to treat this as a full certificate.

Legitimacy
45
Confidence
85%
Panels
1/7

Scored poorly because the file is incomplete or not a full COA, limited panel coverage (1/7), 3 critical findings, and notable note: "Heavy metals only - no purity or identity testing". To improve: upload the full certificate (or the matching sibling purity/endotoxin report) and include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CAG202601
Issue date
2026-01-19

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 0 passed · 0 failed · 1 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Tested · result on file

    Lead, arsenic, cadmium, mercury, or similar limits.

    All Class 1 metals below detection limits; trace Barium (0.474 µg), Copper (0.421 µg), Aluminum (1.04 µg), Calcium (10.2 µg), Sodium (27.3 µg)

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Heavy metals only - no purity or identity testing

    This COA contains ONLY heavy metals testing via EPA methods. No HPLC purity, no mass spec identity, no endotoxin, no microbial testing. This is a partial/supplemental report, not a complete peptide COA.

  • No purity data

    No HPLC, no purity percentage reported. Cannot assess compound quality from heavy metals alone.

  • No identity confirmation

    No mass spectrometry, amino acid analysis, or other identity verification method present.

  • No sample/receipt date

    Only publication date (2026-01-19) is shown. No sample collection or receipt date documented.

  • Lab appears legitimate

    TrustPointe Analytics LLC is a real Michigan-based testing laboratory with verifiable contact information and LIMS verification URL provided.

  • Scope limited to heavy metals

    This appears to be a supplemental heavy metals report only. Client may have separate reports for purity/identity/endotoxin testing. This single document is insufficient for full peptide quality assessment.

  • Client batch ID present

    Client SID CAG202601 and lab sample ID SPL-2777 both documented.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.