Public COA audit

Tirzepatide

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
2/7
Purity (printed)
99.09%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
TIR-006
Identity method
LC-MS/MS
Sample date
2026-07-15
Issue date
2026-07-20

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Tirzepatide confirmed via LC-MS/MS precursor [M+5H]5+ 963.90 Da with MRM transitions

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.09%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    99.09% purity exceeds specification of ≥98%, which is normal and expected for research-grade peptides

  • Comprehensive identity confirmation

    LC-MS/MS with precursor ion and dual MRM transitions (quantifier and qualifier) provides robust identity verification

  • Label accuracy verified

    Net peptide content 10.43 mg vs labeled 10.00 mg gives 104.3% accuracy, exceeding ≥90% specification

  • Clear batch identification

    Sample ID TIR-006 with report number COA-2026-SC-00310

  • Appropriate timeline

    Sample received 2026-07-15, analyzed and reported 2026-07-20 (5-day turnaround)

  • Professional laboratory presentation

    SideChain Analytics with detailed methodology, instrument specifications (Agilent 1290 Infinity II + 6495 QQQ), and appropriate disclaimers

  • Verification system present

    QR code and URL (Peptidetestcanada.ca/verify) with verification code PTC-9QZBS592 provided

  • Limited scope - purity/identity only

    This report covers identity and purity testing only. No heavy metals, microbial, endotoxin, sterility, or residual solvent/water testing included in this file. This is common for split reports where different panels may be issued separately.

  • Professional formatting

    Well-structured report with clear sections, sample photograph, chromatogram, and technical specifications including CAS number, molecular formula, and molecular weight

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.