Tirzepatide

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
2/7
Purity (printed)
99.8%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
MRYVVYD
Identity method
FTIR (USP <197A>)
Sample date
2026-04-23
Issue date
2026-04-26

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of Tirzepatide with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.8%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.8% purity by HPLC (USP <621>) exceeds specification of ≥98%. This is normal for research-grade peptides.

  • Identity confirmed

    FTIR analysis confirms Tirzepatide presence with excipients/fillers, consistent with formulated peptide product.

  • Batch information complete

    Lot number MRYVVYD clearly stated with BT Sample ID 005000039746020.

  • Dates consistent

    Date tested (4/23/2026) precedes issue date (4/26/2026) by 3 days, which is reasonable turnaround time.

  • Lab information provided

    BTLabs (West Palm Beach, FL) with contact information and digital signatures from two scientists (Andrea Castro, AS and Verna Zheng, AS).

  • Limited scope testing

    Testing Purpose explicitly states this COA does not provide information on particulate matter, microbial contamination, or presence of endotoxins. This is a purity/identity-focused report only.

  • Verification URL provided

    Finnrick provides verification URL (https://finnrick.com/verify) with Test Certificate ID: mryvvyd for independent verification.

  • Potency within specification

    HPLC potency assay shows 15.4 mg (102.6%) against labeled 15 mg, within 90-110% specification range.

  • Professional presentation

    Document includes FTIR spectrum and HPLC chromatogram with retention time data. Digital signatures with metadata visible. Dual-branded (BTLabs testing lab and Finnrick customer).

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.