Public COA audit

Tirz 10mg · GLP TZ

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
62
Confidence
78%
Panels
2/7
Purity (printed)
99.714%

Scored lower because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 4 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
665394
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry
Sample date
2026-04-06
Issue date
2026-04-07

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    GLP TZ confirmed via mass spec [M+4H]4+ 1204.20, [M+3H]3+ 1605.55

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.714%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.714% purity by HPLC is excellent and typical for research-grade peptides. Single sharp peak in chromatogram at ~15 min retention time.

  • Mass spec identity confirmed

    Mass spectrum shows expected charge states for tirzepatide: [M+4H]4+ at 1204.20 m/z and [M+3H]3+ at 1605.55 m/z, consistent with molecular weight ~4813 Da.

  • Lot number present

    Lot 665394 clearly stated. Net peptide content 11.64 mg documented.

  • Dates within normal range

    Received 2026-04-06, reported 2026-04-07 (1-day turnaround). Both dates are before today (2026-09-05) and represent reasonable testing timeline.

  • Lab verification unclear

    Freedom Diagnostics claims USA operation and provides FreedomDiagnosticsTesting.com URL, but independent verification of this lab's accreditation, physical address, or regulatory standing is not possible from this document alone. Contact email provided: [email protected].

  • Limited scope - purity/identity only

    This COA covers purity and identity testing only. No heavy metals, microbial, endotoxin, sterility, or residual solvent/water panels present. This is common for basic vendor testing but limits safety assessment. This may be a purity-scoped report; endotoxin/safety testing may exist in separate documents for this lot.

  • Generic template appearance

    Document uses a simple template with stock imagery (vials photo). While not inherently suspicious, the layout is basic and could be easily replicated. Signature appears to be a stylized font rather than handwritten.

  • Principal Chemist identification

    Alex Johnson listed as Principal Chemist. Name is common and no credentials (PhD, certifications) or license numbers provided for independent verification.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.