Public COA audit

Tirzepatide

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
3/7
Purity (printed)
99.9%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
2jx3cqq
Identity method
HPLC-UV-MS
Sample date
2026-06-04
Issue date
2026-06-15

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 2 passed · 0 failed · 1 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    >99.9%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

    2.5 EU

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    >99.9% purity by HPLC-UV/MS with clean chromatogram showing single dominant peak at ~7 minutes retention time

  • Mass spectral confirmation

    Mass spectrum shows expected charge states for Tirzepatide (m/z 1613.4, 1216.0, etc.) with ID confirmed by comparison to authentic standard

  • Batch/lot number present

    Batch 2jx3cqq clearly documented with Lab # 206580 and Project 145283

  • Dates within normal range

    Sample received 2026-06-04, testing performed 2026-06-06 to 2026-06-11, report issued 2026-06-15 - all dates are consistent and on or before 2026-07-29

  • Branding inconsistency

    Document shows dual branding: header/footer say 'Finnrick Analytics' and 'Finnrick.com' but signature block, methods, and address reference 'Krause Analytical LLC' at 8127 Mesa Drive Suite B-206 Austin, TX 78759. This suggests Finnrick may be a reseller/distributor rather than the actual testing lab, or there is a partnership arrangement not clearly explained on the COA

  • Verification URL provided but not independently confirmed

    Document provides verification URL https://finnrick.com/verify with certificate ID 2jx3cqq, but independent verification of this URL's legitimacy cannot be performed from the document alone

  • Limited testing panels

    Only purity, identity, and endotoxin testing performed. No heavy metals results reported despite method being described on page 4, and no microbial, sterility, or residual solvent testing. This is not uncommon for research-grade peptides but limits quality assurance

  • Professional presentation

    Document includes detailed methods summary, chromatogram, mass spectrum, proper USP method references, and laboratory director signature

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.