Public COA audit

Thymosin Alpha 1 · Thymosin α1

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
3/7
Purity (printed)
99.9%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
7xphgye
Identity method
HPLC-UV-MS
Sample date
2026-06-04
Issue date
2026-06-15

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    >99.9%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    0.60 EU

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    HPLC purity >99.9% with clean chromatogram showing single dominant peak at ~6 min retention time

  • Mass spectral confirmation

    MS data shows expected m/z peaks (1037.8, 778.7, 1556.2) consistent with Thymosin α1 charge states; ID confirmed

  • Unusual batch/lot format

    Batch number '7xphgye' appears to be a random alphanumeric string rather than typical sequential or date-based lot numbering

  • Dual branding inconsistency

    Document shows both 'Finnrick Analytics' and 'Krause Analytical LLC' branding with different addresses (Finnrick.com vs 8127 Mesa Drive Austin TX); unclear relationship between entities

  • Verification URL domain mismatch

    Verification URL points to finnrick.com but lab director signature is from Krause Analytical LLC

  • Limited testing scope

    Only purity, identity, and endotoxin panels performed; no heavy metals, microbial, sterility, or residual solvent testing despite methods being described on page 4

  • Professional presentation

    Document includes detailed chromatogram, mass spectrum, methods summary, and proper USP method references

  • Dates within normal range

    Sample received 2026-06-04, testing 2026-06-10/11, report issued 2026-06-15 - all dates are sequential and reasonable

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.