Public COA audit

Tesamorelin

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
3/7
Purity (printed)
99.81%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), 4 soft concerns, and notable note: "High HPLC purity". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
8dpa32k
Identity method
HPLC-UV-MS
Sample date
2026-02-26
Issue date
2026-03-02

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 2 passed · 0 failed · 1 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.81%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

    0.67 EU

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.81% chromatographic purity is excellent and normal for research-grade peptides

  • Mass spectral confirmation

    Identity confirmed by HPLC-UV-MS with reference spectrum match shown on page 2

  • Batch/lot number present

    Lot 8dpa32k clearly stated with vial photos

  • Dates within normal range

    Sample received 2/26/2026, report issued 3/2/2026 (4-day turnaround), endotoxin tested 2/28/2026

  • Lab name inconsistency

    Document header shows 'Finnrick Analytics' and 'Finnrick.com' but footer and signature reference 'Krause Analytical LLC' with Austin, TX address. This dual branding is unusual but may indicate Finnrick is a reseller/distributor using Krause as contract lab.

  • Verification URL domain mismatch

    Verification URL is https://finnrick.com/verify but lab performing analysis is Krause Analytical LLC. Cannot verify if this URL is functional or legitimate without external check.

  • Endotoxin testing present

    Endotoxin result 0.67 EU reported using USP 86 (LAL method) on 2/28/2026

  • Heavy metals method described but no results

    Page 3 describes ICP-MS method for metals (USP/NF 233) but no results are shown in the certificate. This may be a separate test not performed for this lot.

  • Missing microbial and sterility panels

    No microbial contamination or sterility testing results shown. Common for research-grade peptides but limits quality assurance.

  • Professional presentation

    Document includes chromatogram, mass spectrum comparison, detailed methods, signature, and vial photos. Formatting is consistent with legitimate analytical lab reports.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.