Public COA audit

BPC-157 · TB-500

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
1/7

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), 2 soft concerns, and notable note: "Endotoxin testing present". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
Test-ED7
Sample date
2026-06-05
Issue date
2026-06-17

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    2.852 EU/Vial

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin testing present

    Document shows endotoxin analysis with result of 2.852 EU/Vial, which is below the stated 10 EU/vial threshold. This is an endotoxin-specific report.

  • Limited scope report

    This is an endotoxin-only test report. No purity, identity, heavy metals, microbial, sterility, or residual solvent panels are present in this document. This may be part of a split testing approach where other panels are reported separately.

  • Batch number present

    Batch/lot number Test-ED7 is clearly stated and matches the vial label shown in the photograph.

  • Dates are consistent and valid

    Testing ordered 14 May 2026, sample received 05 June 2026, analysis conducted 17 June 2026. All dates are sequential and on or before the current date (2026-09-05).

  • Known testing laboratory

    Janoshik Analytical is a recognized third-party testing laboratory in the peptide/research compound space. Contact information and verification URL are provided.

  • Verification system present

    Document includes verification URL (www.janoshik.com/verify/) with unique key 39WVPJYV7VNF and QR code for independent verification.

  • Professional presentation

    Report follows Janoshik's standard format with clear sections, signature, and supporting photographs of the sample vial and LAL test plates.

  • No purity data in this report

    This endotoxin-focused report does not contain HPLC purity or identity confirmation. For a complete assessment of this blend, a separate purity/identity report would be expected.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.