Public COA audit

TB-500 · Thymosin β4

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
4/7
Purity (printed)
99.91%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (4/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
7wdwhn8
Identity method
HPLC-UV-MS
Sample date
2025-11-26
Issue date
2025-12-06

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

4 of 7 present · 2 passed · 0 failed · 2 reported · 3 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.91%

  • Heavy metals

    Tested · result on file

    Lead, arsenic, cadmium, mercury, or similar limits.

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    99.91% purity by HPLC-UV/MS is excellent and typical for research-grade peptides

  • Identity confirmed

    Mass spectrum matches authentic Thymosin β4 standard with characteristic m/z peaks (711, 622, 829, 994)

  • Potency within specification

    10.9 mg measured vs 10 mg label claim = 109.1% of label, within typical acceptance range

  • Batch/lot number present

    Lot 7wdwhn8 clearly identified

  • Dates consistent

    Sample received 2025-11-26, tested 2025-11-28, report issued 2025-12-06 - all dates are logical and sequential

  • Established testing laboratory

    Krause Analytical LLC is a known peptide testing lab in Austin, TX with verification URL provided

  • Multiple testing panels documented

    Methods summary on page 3 describes purity/potency/identity (USP/NF 621), endotoxins (USP/NF 85), and metals (USP/NF 233) testing protocols

  • Endotoxin and metals results not shown

    Methods for endotoxin (LAL) and heavy metals (ICP-MS) are described on page 3, but numerical results are not presented on this certificate - may be on separate report or pending

  • Professional presentation

    Document includes chromatogram, mass spectrum comparison, signature of Laboratory Director Mark C. Krause, and comprehensive methods summary

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.