Public COA audit
TB-500 · Thymosin Beta-4
Audited July 28, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 83%
- Panels
- 2/7
- Purity (printed)
- 99.375%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- TB1009232025-J
- Identity method
- HPLC with UV Detection Coupled with Mass Spectrometry
- Sample date
- 2025-09-24
- Issue date
- 2025-09-25
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Thymosin Beta-4 confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.375%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
99.375% purity by HPLC-MS is within normal range for research-grade peptides
Identity confirmed
Mass spectrometry data shows expected molecular ion peaks for Thymosin Beta-4 with multiple charge states visible
Batch information present
Lot number TB1009232025-J clearly stated with net peptide content 10.39 mg
Dates within normal range
Received 9/24/2025, reported 9/25/2025 - one day turnaround is reasonable
Lab verification unclear
Freedom Diagnostics website listed but independent verification of lab accreditation/credentials not provided on COA
Limited testing scope
Only identity and purity panels performed; no heavy metals, microbial, endotoxin, sterility, or residual solvent testing
Professional presentation with minor inconsistencies
Document includes chromatogram and mass spec data with product photos; however, some table formatting appears basic and signatory information minimal
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.