Public COA audit
TB-500 · Thymosin Beta-4
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 83%
- Panels
- 3/7
- Purity (printed)
- 99.817%
Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), 3 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- TB1012222025-J
- Identity method
- HPLC with UV Detection Coupled with Mass Spectrometry
- Sample date
- 2026-02-23
- Issue date
- 2026-02-24
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Thymosin Beta-4 confirmed via LCMS/MS
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.817%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
≤ 0.05 EU/mL (both replicates)
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
99.817% purity via HPLC is excellent and within normal range for research-grade peptides
Identity confirmed
Mass spectrometry data shows expected molecular ion peaks for Thymosin Beta-4 with charge states visible
Endotoxin testing performed
Duplicate endotoxin testing with ≤ 0.05 EU/mL threshold, both replicates passed
Batch information present
Lot number TB1012222025-J clearly stated with net peptide content 11.99 mg
Dates within acceptable range
Received 02/23/2026, reported 02/24/2026 - one day turnaround is reasonable
Lab verification limited
Freedom Diagnostics claims USA operation with searchable website, but independent verification of lab accreditation/credentials not provided on COA itself
Limited testing scope
No heavy metals, microbial, sterility, or residual solvent/water testing shown - common for basic peptide COAs but limits comprehensive quality assurance
Generic template appearance
COA uses relatively simple formatting with stock product photos; professional but less detailed than some institutional lab reports
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.