Public COA audit

TB-500

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
88%
Panels
3/7
Purity (printed)
99.8%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), 2 soft concerns, and notable note: "High HPLC purity". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-TB510-2603-1
Identity method
FTIR (USP <197A>)
Sample date
2026-04-02
Issue date
2026-04-05

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of TB-500 with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.8%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    18.7 EU/vial (limit: 40 EU/vial)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.8% purity is excellent and within normal range for research-grade peptides

  • FTIR confirmation

    Identity confirmed via FTIR spectroscopy with characteristic peptide bands; excipients noted

  • Potency significantly exceeds specification

    HPLC potency assay shows 122-138% of labeled 10mg (12.2-13.8mg actual), exceeding the 90-110% specification range. This overfill is common in research peptides but technically fails the stated spec.

  • Endotoxin testing present

    Separate endotoxin report (page 3) shows gel clot LAL test with 18.7 EU/vial result, well below 40 EU/vial limit

  • Consistent lot number

    Lot CR-TB510-2603-1 consistent across both purity and endotoxin reports

  • Dates are valid

    Sample date 2026-04-02, issue date 2026-04-05, endotoxin test 2026-04-08, all on or before current date 2026-09-05

  • BTLabs contact information

    Lab name, address (West Palm Beach, FL), phone, email, and website provided with QR code

  • Professional multi-page report

    Three-page report with FTIR spectrum, HPLC chromatogram, and separate endotoxin certificate; signatures from two scientists

  • Limited scope explicitly stated

    Testing purpose explicitly states it does not provide information on particulate matter or microbial contamination (sterility). Heavy metals and residual solvents not tested.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.