SS-31

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
88
Confidence
92%
Panels
2/7
Purity (printed)
99.48%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
DPS-5133749
Identity method
UPLC/MS
Issue date
2026-07-31

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    SS-31 confirmed by MS (m/z 638.78, expected ~639.8)

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.48%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    UPLC purity of 99.48% exceeds specification (>98%). This is normal for research-grade peptides and supported by clean chromatogram.

  • Identity confirmed by MS

    Mass spectrometry shows expected molecular ion at m/z 638.78 (theoretical ~639.8 g/mol for SS-31). UPLC retention time consistent across both pages.

  • Lot number present

    Lot DPS-5133749 clearly stated on both pages.

  • Analysis date valid

    Analysis date 07/31/2026 is on or before current date (2026-09-05) and is therefore valid.

  • Lab identification present

    Horizon Analytical identified with contact email and verification URL. Signed by Aleksey Yevtodiyenko PhD, Research and Formulation Chemist.

  • Purity/identity report file

    This certificate file looks like a purity/identity report. Many vendors publish a separate endotoxin report for the same lot — missing endotoxin on this file alone does not prove the lot was never tested.

  • Professional presentation

    Document includes QR code for validation, chromatograms, mass spectra, and professional formatting consistent with legitimate analytical lab reports.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.