Public COA audit
(ShredX) AOD9604 · AOD-9604
Audited July 28, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 82%
- Panels
- 2/7
- Purity (printed)
- 100%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- SHRED-0001
- Identity method
- LC-MS with UV detection
- Sample date
- 2024-12-27
- Issue date
- 2025-01-04
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
AOD-9604
Purity
Tested · passed · core
Reported purity percentage for the analyte.
100%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity achieved
100% purity reported via LC-MS, which is within normal range for research-grade peptides
Identity confirmed
Compound identity matches specification (AOD-9604) with LC-MS and chromatogram data provided
Lab verification needed
BioRegen appears to be the testing lab, but independent verification of lab credentials and accreditation status is recommended. The verification URL (bioregen.com/verify) should be checked.
Limited testing scope
Only identity and purity panels present. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing reported. This is common for basic COAs but limits safety assurance.
Batch information present
Batch/Lot number SHRED-0001 clearly documented
Dates documented
Sample received 2024-12-27, analysis conducted 2025-01-04. Both dates are reasonable and in the past relative to current date (2026-07-28).
Client information raises questions
Client listed as 'Biolongevity Labs' with contact information. The relationship between client and testing lab should be clarified for transparency.
Timing & next steps
Practical follow-ups based on document age and gaps.
coa age
This COA was issued over a year ago (570 days) — consider whether a retest is warranted for this batch.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.