Public COA audit

Sermorelin

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
88%
Panels
2/7
Purity (printed)
99.35%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
B-3441701-P
Identity method
UPLC/MS
Sample date
2026-07-05
Issue date
2026-07-09

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Sermorelin confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.35%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Identity confirmed by MS

    Mass spectrometry data shows expected molecular ion pattern consistent with Sermorelin (MW ~3357.9 g/mol)

  • Lot number clearly stated

    Lot B-3441701-P with -P suffix indicating this is a purity/identity-focused report

  • Dates are valid and logical

    Lab received 2026-07-05, analysis conducted 2026-07-09 (4-day turnaround is reasonable)

  • Lab credentials present

    Signed by Aleksey Yevtodiyenko PhD, Research and Formulation Chemist; contact email and verification URL provided

  • Purity/identity report file

    This certificate file looks like a purity/identity report. Many vendors publish a separate endotoxin report for the same lot — missing endotoxin on this file alone does not prove the lot was never tested.

  • Professional presentation

    Clean layout with QR code for validation, detailed chromatograms and mass spectra on two pages, consistent branding

  • High purity confirmed

    UPLC purity of 99.35% meets specification >98% with clean chromatogram showing single dominant peak

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.