Public COA audit

Selank

Audited July 28, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
2/7
Purity (printed)
99.39%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 3 soft concerns, and notable note: "High purity result". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
OC-SK10-103
Identity method
HPLC-UV/VIS
Issue date
2026-07-13

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 1 passed · 0 failed · 1 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · result on file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    HPLC chromatogram shown

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.39%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity result

    HPLC purity of 99.39% is within normal range for research peptides

  • Chromatogram present

    HPLC chromatogram included showing retention time and peak data

  • Lab verification uncertain

    Vanguard Laboratory (Olympia, WA) listed with ISO 17025:2017 accreditation badge, but independent verification of this specific lab's accreditation status not possible from document alone

  • Batch information present

    Lot Number OC-SK10-103 and Laboratory ID V260624-8 clearly stated

  • Issue date valid

    Date Released 7/13/2026 is within acceptable range (on or before 2026-07-28)

  • Limited testing scope

    Only purity and identity testing performed; no heavy metals, microbial, endotoxin, sterility, or residual solvent testing shown

  • Watermark present

    Large 'ONEDAY COMPOUNDS' watermark overlaid on chromatogram may indicate this is a customer copy or sample report

  • Dual signatures

    Report signed by Laboratory Director (Dustin Newman) and Operations Manager (Tori Johnson) on 7/13/2026

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.