Public COA audit
Retatrutide
Audited September 5, 2026
Missing panels or key metadata — not enough evidence to treat this as a full certificate.
- Legitimacy
- 62
- Confidence
- 78%
- Panels
- 2/7
Scored lower because the file is incomplete or not a full COA, limited panel coverage (2/7), 2 soft concerns, and notable note: "Purity percentage not stated". To improve: upload the full certificate (or the matching sibling purity/endotoxin report) and include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- APR-4311595
- Identity method
- UPLC, Mass Spectrometry (MS)
- Issue date
- 2026-03-11
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 0 passed · 0 failed · 2 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · result on file · core
Compound identity confirmed (e.g. HPLC, mass spec).
Confirmed by UPLC and MS
Purity
Tested · result on file · core
Reported purity percentage for the analyte.
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Purity percentage not stated
UPLC chromatogram is present but no numerical purity value is provided on this page
Identity confirmed by dual methods
Both UPLC and Mass Spectrometry data are present. PubChem CID 171390338 is referenced for Retatrutide (30mg)
Lot number clearly stated
APR-4311595
Dates within acceptable range
Received 2026-03-04, Analysis conducted 2026-03-11. Both dates are before today (2026-09-05)
Testing lab identified
Horizon Analytical with searchable URL horizonanalytical.com and contact email provided
Purity/identity report file
This certificate file looks like a purity/identity report. Many vendors publish a separate endotoxin report for the same lot — missing endotoxin on this file alone does not prove the lot was never tested.
Professional presentation
Clean layout with lab branding, chromatograms, and mass spec data clearly displayed
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.