Public COA audit

Retatrutide

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
88%
Panels
3/7
Purity (printed)
99.9%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
ckdwpqc
Identity method
HPLC-UV-MS
Sample date
2026-01-16
Issue date
2026-02-04

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    >99.9%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    <0.5 EU/vial

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    HPLC purity >99.9% is normal for research-grade peptides and supported by clean chromatogram with single dominant peak at 6.41 min

  • Mass spectrum confirmation

    Mass spectrum shows expected m/z peaks (1195, 1586) matching reference standard for Retatrutide, confirming identity

  • Potency within specification

    Measured 5.52 mg vs 5 mg label claim = 110.3% of label, within typical acceptable range for lyophilized peptides

  • Batch/lot number present

    Batch/Lot ckdwpqc clearly stated and visible on vial photos

  • Dates are logical and current

    Sample received 2026-01-16, testing 2026-01-26 to 2026-02-01, report issued 2026-02-04 — all dates are sequential and on or before 2026-07-29

  • Established testing laboratory

    Krause Analytical LLC is a known third-party analytical lab in Austin, TX with verifiable address and director signature

  • Verification URL provided

    Certificate includes verification URL https://finnrick.com/verify with certificate ID ckdwpqc for independent validation

  • Limited testing panels

    Only purity, identity, and endotoxin testing performed. No heavy metals, microbial, sterility, or residual solvent testing shown, though methods summary describes metals testing capability

  • Professional presentation

    Multi-page COA with detailed methods summary, chromatogram, mass spectra, vial photos, and proper USP method references

  • Duplicate endotoxin entries

    Endotoxin test appears twice with identical results (<0.5 EU/vial, USP 86, 1/26/2026) — likely formatting artifact but unusual

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.