Public COA audit
Retatrutide · Retatrutide 60mg
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 85%
- Panels
- 2/7
- Purity (printed)
- 99.945%
Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 3 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- Purple Cap
- Identity method
- GLP RT
- Sample date
- 2026-04-09
- Issue date
- 2026-04-11
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
GLP RT
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.945%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
HPLC purity of 99.945% with mass spectrometry confirmation showing expected molecular ion peaks [M+3H]3+ 1577.95 and [M+3H+K]4+ 1193.00
Identity confirmed
GLP RT identity method with mass spec data consistent with retatrutide
Non-standard lot identifier
Lot number 'Purple Cap' is descriptive rather than a formal alphanumeric batch code, which is unusual for professional lab reporting
Dates within normal range
Received 2026-04-09, reported 2026-04-11 (2-day turnaround is reasonable)
Lab verification needed
Freedom Diagnostics claims USA operation with searchable URL FreedomDiagnosticsTesting.com - independent verification of lab accreditation recommended
Limited testing scope
This report covers purity and identity only. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing shown on this document. May be a purity-focused report with other panels tested separately or not at all.
Professional presentation
Document includes chromatogram, mass spectrum, product photo, and clear data tables with proper labeling
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.