Public COA audit
Retatrutide
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 3/7
- Purity (printed)
- 99.9%
Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- ph7cfp5
- Identity method
- HPLC-UV-MS
- Sample date
- 2026-06-09
- Issue date
- 2026-06-16
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
>99.9%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
<0.5 EU
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Excellent chromatographic purity
HPLC-UV/MS shows >99.9% purity with clean chromatogram showing single dominant peak at ~7 minutes retention time
Mass spectral confirmation
Mass spectrum shows expected m/z peaks (1586.0, 1578.8) consistent with Retatrutide molecular weight, ID confirmed by comparison to authentic standard
Batch/lot number present
Lot ph7cfp5 clearly marked on certificate and vial images
Dates within normal range
Sample received 2026-06-09, testing completed 2026-06-10 to 2026-06-14, report issued 2026-06-16 - all dates are sequential and reasonable
Established testing laboratory
Krause Analytical LLC is a known contract testing lab in Austin, TX. Certificate includes verification URL, lab director signature, and detailed methods summary
Core testing panels completed
Certificate includes purity/potency (92.9% of label claim, 9.29mg recovered from 10mg vial), identity confirmation, and endotoxin testing (<0.5 EU). Heavy metals method listed but results not shown on this certificate
Professional presentation
Multi-page certificate with detailed chromatogram, mass spectrum, methods summary, and vial photographs. Consistent branding between Finnrick (vendor) and Krause Analytical (testing lab)
Heavy metals method described but not reported
Page 4 describes USP/NF 233 ICP-MS method for metals testing, but no results appear in the certificate. This may be a separate test or not performed for this batch
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.