Public COA audit

Retatrutide

Audited September 5, 2026

Consistent with a legitimate COA

Document structure and test panels align with what we expect from authentic lab reports.

Legitimacy
92
Confidence
93%
Panels
3/7
Purity (printed)
99.82%

Scored high because document structure and panels look consistent with authentic lab output and limited panel coverage (3/7). To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
nv8k3eh
Identity method
HPLC-UV-MS
Sample date
2026-02-06
Issue date
2026-02-22

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.82%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    <0.1 EU

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    Chromatographic purity of 99.82% with HPLC-UV/MS method, supported by clean chromatogram showing dominant peak at retention time 6.62 minutes

  • Identity confirmed by mass spectrometry

    Mass spectrum matches authentic Retatrutide standard; CAS 2381089-83-2 provided; mass spectrum data shown on page 2

  • Batch/lot number present

    Lot nv8k3eh clearly marked; visible on vial photos and throughout document

  • Dates are consistent and valid

    Sample received 2/6/2026, testing performed 2/12-2/14/2026, report issued 2/22/2026 - all dates are logical and sequential

  • Established testing laboratory

    Krause Analytical LLC is a known third-party peptide testing lab in Austin, TX; document includes verification URL, lab director signature, and detailed methods

  • Core panels present

    Identity, purity, and endotoxin testing completed; heavy metals method described but not run on this sample; microbial/sterility/residual solvents not included

  • Professional formatting with supporting data

    Multi-page report includes chromatogram, mass spectrum comparison, detailed methods summary, and vial photos; consistent branding for both Finnrick and Krause Analytical

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.