Public COA audit

Reta · Retatrutide

Audited September 5, 2026

Incomplete documentation

Missing panels or key metadata — not enough evidence to treat this as a full certificate.

Legitimacy
45
Confidence
82%
Panels
1/7

Scored poorly because the file is incomplete or not a full COA, limited panel coverage (1/7), 3 critical findings, and notable note: "Endotoxin-only report". To improve: upload the full certificate (or the matching sibling purity/endotoxin report) and include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
665394
Identity method
LCMS/MS
Sample date
2026-04-06
Issue date
2026-04-07

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Pass (Replicate 1 and 2)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin-only report

    This COA only reports endotoxin testing results. No purity percentage, identity confirmation, chromatogram, mass spec data, or other analytical panels are present. This appears to be a partial/split report focused solely on endotoxin testing.

  • No purity data

    Despite mentioning LCMS/MS analysis in the disclaimer text, no actual purity percentage or chromatographic data is provided in this document.

  • No identity confirmation

    No mass spectrometry results, molecular weight confirmation, or identity verification data is included.

  • Lot number present

    Lot 665394 clearly stated for product 'Reta 10mg'.

  • Dates within valid range

    Received 2026-04-06, Reported 2026-04-07. Both dates are before the current date of 2026-09-05 and show reasonable turnaround time.

  • Limited lab information

    Freedom Diagnostics is identified with a website and email, but no physical address, accreditation information, or analyst credentials beyond a signature are provided.

  • Minimal technical detail

    The endotoxin results show only Pass/Pass for two replicates with no quantitative EU values, threshold limits, or method specifics (LAL, chromogenic, gel-clot, etc.).

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.