Public COA audit

MOTS-C

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
1/7
Purity (printed)
99.336%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), 2 soft concerns, and notable note: "High purity reported". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
MOT10N041525
Sample date
2025-04-28
Issue date
2025-04-29

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 0 passed · 0 failed · 1 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Tested · result on file · core

    Reported purity percentage for the analyte.

    99.336%; 99.304%; 99.377%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity reported

    Three replicate measurements show purity values of 99.336%, 99.304%, and 99.377%, which is consistent with high-quality research peptide synthesis. This is normal and not suspicious.

  • No identity confirmation method stated

    The report does not specify the analytical method used to confirm peptide identity (e.g., mass spectrometry). Only purity values are provided.

  • Limited testing scope

    This report only includes purity testing. No identity confirmation, heavy metals, microbial, endotoxin, sterility, or residual solvent/water testing is documented on this report. This may be a purity-only report, and other panels may exist in separate documents.

  • Batch number present

    Batch/lot number MOT10N041525 is clearly stated.

  • Dates are consistent and valid

    Testing ordered 18 APR 2025, sample received 28 APR 2025, analysis conducted 29 APR 2025. All dates are logical, sequential, and on or before the current date (2026-09-05).

  • Known testing laboratory

    Janoshik is a recognized third-party analytical laboratory for peptide and compound testing. Contact information and verification URL are provided.

  • Professional formatting with verification key

    Report includes task number #63513, QR code, verification URL (www.janoshik.com/verify/), unique key (FPL583ELYFYP), and signature. Format is consistent with known Janoshik reports.

Timing & next steps

Practical follow-ups based on document age and gaps.

  • coa age

    This COA was issued over a year ago (494 days) — consider whether a retest is warranted for this batch.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.