Public COA audit

NAD+ · NAD+ 1000mg

Audited July 28, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
88
Confidence
85%
Panels
4/7
Purity (printed)
99.24%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
NAD1000-062026-2
Identity method
LC-MS
Sample date
2026-06-24
Issue date
2026-06-26

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

4 of 7 present · 4 passed · 0 failed · 0 reported · 3 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    NAD+ Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.24%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Tested · passed

    Bioburden / microbial limits testing.

    No Detectable Microbial DNA

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Pass (≤0.05 EU/mL)

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    HPLC-UV purity of 99.24% is within normal range for research-grade NAD+. Two vials tested with consistent results (99.23% and 99.24%).

  • Identity confirmed by LC-MS

    Mass spectrometry confirmation provided with chromatogram showing clean NAD+ peak. Mass spectrum included showing expected fragmentation pattern.

  • Comprehensive safety testing

    Endotoxin testing (USP <85> compliant) and microbial analysis (PCR-based) both passed. Duplicate endotoxin replicates performed.

  • Batch information complete

    Lot number NAD1000-062026-2 clearly stated. Net content measured for both vials (98.40 mg and 105.35 mg, average 101.88 mg).

  • Dates appropriate

    Received 2026-06-24, reported 2026-06-26. Two-day turnaround is reasonable for this testing scope.

  • Lab verification limited

    Freedom Diagnostics Testing website and contact provided, but no accreditation logos (ISO 17025, GMP, etc.) visible on COA. Search code provided for verification (Whol2606240018).

  • Missing panels

    Heavy metals, sterility, and residual solvent/water content testing not performed. This is common for basic research-grade testing but limits comprehensive quality assessment.

  • Professional presentation

    Well-formatted COA with clear sections, appropriate disclaimers for research use only, signature present, chromatogram and mass spectrum included.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.