Public COA audit

NAD+

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
3/7
Purity (printed)
99.505%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), 3 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
0003
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry (LCMS/MS)
Sample date
2025-11-19
Issue date
2025-11-21

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    NAD+ confirmed by mass spectrometry ([M+H]+ 663.93, [M+2H]2+ 332.43)

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.505%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    ≤ 0.05 EU/mL (both replicates)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.505% purity by HPLC is excellent and within normal range for research-grade NAD+

  • Mass spectrometry confirmation

    Identity confirmed with appropriate mass spec data showing [M+H]+ and [M+2H]2+ ions consistent with NAD+

  • Endotoxin testing included

    Separate endotoxin report (page 2) shows duplicate testing per USP <85>, both replicates pass at ≤0.05 EU/mL

  • Batch number present

    Lot 0003 clearly identified

  • Dates within normal range

    Received 11/19/2025, reported 11/21/2025 - 2-day turnaround is reasonable

  • Limited lab verification information

    Freedom Diagnostics claims USA operation with searchable verification, but no physical address, accreditation details, or independent third-party validation provided

  • Split report format

    Purity/identity and endotoxin testing presented as separate accession numbers (2511190025 vs 2511190026) for same lot, which is unusual but not necessarily illegitimate

  • Limited testing scope

    No heavy metals, microbial contamination, sterility, or residual solvent/water content testing reported

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.