Public COA audit
NAD+
Audited September 5, 2026
Multiple signals on this document conflict with known lab formats or verification patterns.
- Legitimacy
- 15
- Confidence
- 92%
- Panels
- 4/7
Scored poorly because audit signals point to fabrication or reused paperwork, limited panel coverage (4/7), 4 critical findings, and notable note: "Mass spectral match failed". To improve: replace this file with an original lab certificate that verifies on the lab portal and include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- 4k43fmh
- Identity method
- HPLC-UV-MS
- Sample date
- 2026-06-04
- Issue date
- 2026-06-15
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
4 of 7 present · 0 passed · 1 failed · 3 reported · 3 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · failed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Incorrect
Purity
Tested · result on file · core
Reported purity percentage for the analyte.
ND
Heavy metals
Tested · result on file
Lead, arsenic, cadmium, mercury, or similar limits.
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · result on file · core
LAL or chromogenic endotoxin assay.
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Mass spectral match failed
The COA explicitly states 'Mass Spectral Match: Incorrect' — the sample did NOT match the expected NAD+ standard. This is a fundamental failure of identity confirmation.
Chromatographic purity not detected
Purity result shows 'ND' (not detected) with no percentage value. This means no quantifiable NAD+ was found in the sample.
NAD+ quantity not detected
The NAD+ analyte row shows 'ND' for result, meaning the compound was not detected at the stated label claim of 500 mg.
Dual branding inconsistency
Document shows both 'Finnrick Analytics' and 'Krause Analytical LLC' branding with different addresses. Header says Finnrick.com, footer and signature say Krause Analytical. This dual identity is unusual for a legitimate lab report.
Verification URL domain mismatch
Verification URL is https://finnrick.com/verify but the lab is identified as Krause Analytical LLC. The domain 'finnrick.com' does not match the lab name.
Methods summary describes tests not performed
Page 4 includes detailed methods for Endotoxins (USP/NF 86) and Metals (USP/NF 233), but page 1 shows no results for these tests. The methods summary appears to be a generic template rather than specific to this analysis.
Complete analytical failure
This COA documents a complete failure: the sample did not match NAD+, no purity could be determined, and no NAD+ was detected. This is not a passing certificate — it documents that the sample is NOT what was claimed.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.