Public COA audit

MTS-31 · SS-31

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
5/7
Purity (printed)
99.61%

Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-MTS31-10MG-2607-Black
Identity method
HPLC-RTM (retention time match)
Sample date
2026-07-19
Issue date
2026-07-31

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Confirmed (SS-31)

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.61%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    As: 0.6662 ppm, Cd: 0.2141 ppm, Pb: 0.6611 ppm, Hg: 0.521 ppm, Cr: 5.62 ppm

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    0.094 EU/mL

  • Sterility

    Tested · passed

    Sterility testing where applicable.

    No Growth

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.61% purity by HPLC with conformity testing across 3 samples (mean 99.52%, std dev 0.1087%) demonstrates excellent batch consistency

  • Identity confirmed

    MTS-31 (SS-31) confirmed by HPLC retention time match with reference standard; includes fentanyl screen (not detected)

  • Batch information complete

    Lot CR-MTS31-10MG-2607-Black, COA-2026-954683, Accession ACC-2026-11193, labeled 10mg with net peptide content 10.48mg

  • Timeline appropriate

    Received 2026-07-19, analyzed and issued 2026-07-31 (12-day turnaround)

  • Lab credentials present

    ILS Laboratories, San Diego CA, ISO/IEC 17025 accredited, signed by Dr. Greg Kalyuzhny (Lab Director), includes verification URL and QR code with access code KZ6QYJ94

  • Comprehensive testing panel

    Five panels present: purity/identity (HPLC), heavy metals (ICP-MS), sterility (PCR), endotoxin (USP <85>). Missing: microbial count, residual solvents/water content

  • Microbial panel absent

    No microbial enumeration (TAMC/TYMC) testing shown; sterility (PCR) present but does not replace quantitative microbial count

  • Professional presentation

    Well-formatted 2-page report with chromatogram, conformity data table, detailed methodology notes, and clear pass/fail indicators

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.