Public COA audit
motsc · MOTS-c
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 45
- Confidence
- 85%
- Panels
- 2/7
Scored poorly because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 1 critical finding, and notable note: "Identity Test Failed". To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- WPMS10P00043
- Identity method
- LC-MS
- Sample date
- 2026-06-04
- Issue date
- 2026-06-07
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 0 passed · 1 failed · 1 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · failed · core
Compound identity confirmed (e.g. HPLC, mass spec).
No Analyte Detected
Purity
Tested · result on file · core
Reported purity percentage for the analyte.
N/A
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Identity Test Failed
LC-MS identity test shows 'No Analyte Detected' and Identity field explicitly marked as 'Failed'. The sample did not contain the expected peptide (MOTS-c).
Purity Not Determined
Purity (HPLC-UV) result is listed as N/A. No purity percentage was determined or reported.
Limited Testing Scope
This COA only includes identity and purity panels. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing is present. This is a purity/identity-scoped report only.
Batch Number Present
Lot number WPMS10P00043 clearly documented with search code Pine2606040464.
Dates Valid
Received 2026-06-04, Reported 2026-06-07. Both dates are valid and show reasonable 3-day turnaround.
Lab Verification Uncertain
Freedom Diagnostics Testing appears to be a legitimate testing service, but the failed identity test raises questions about sample handling, labeling, or vendor accuracy.
Professional Presentation
Document includes chromatogram, mass confirmation section, signature, and standard disclaimer language. Formatting appears consistent with legitimate testing lab reports.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.