Public COA audit
MOTS-c
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 95
- Confidence
- 92%
- Panels
- 5/7
- Purity (printed)
- 99.91%
Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 2 soft concerns.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- CR-MTS10-0309-1
- Identity method
- HPLC retention time comparison with reference standard
- Sample date
- 2026-05-06
- Issue date
- 2026-05-11
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.91%
Heavy metals
Tested · passed
Lead, arsenic, cadmium, mercury, or similar limits.
All Not Detected (As, Cd, Cr, Hg, Pb)
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
0.09 EU/mL
Sterility
Tested · passed
Sterility testing where applicable.
No Growth
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity with conformity testing
99.91% purity confirmed across 3 independent samples (mean 99.86%, std dev 0.0356%), demonstrating batch consistency
Identity confirmed
MOTS-c identity confirmed by HPLC retention time comparison with reference standard across all 3 conformity samples
Comprehensive testing panel
Full QC panel includes purity/identity (HPLC), heavy metals (ICP-MS), sterility (PCR), and endotoxin (USP <85>)
Clear batch identification
Lot CR-MTS10-0309-1, Accession ACC-2026-2076, COA COA-2026-TCT0QG with verification URL and access code
Appropriate timeline
Received 2026-05-06, analyzed and issued 2026-05-11 (5-day turnaround)
ISO/IEC 17025 accredited lab
ILS Laboratories claims ISO/IEC 17025 accreditation with complete contact information and verification portal
Missing microbial panel
No microbial contamination testing (e.g., total aerobic count, yeast/mold) present; only sterility by PCR shown
No residual solvent/water content
No Karl Fischer water content or residual solvent analysis reported
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.