Public COA audit

Melanotan II

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
88
Confidence
92%
Panels
2/7
Purity (printed)
99.8%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
WL-ML10-P00518
Identity method
FTIR (USP <197A>) and HPLC (USP <621>)
Sample date
2026-06-08
Issue date
2026-06-12

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of Melanotan II with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.8%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.8% purity by HPLC (USP <621>) exceeds ≥98% specification. This is normal for research-grade peptides.

  • Identity confirmed

    FTIR spectrum confirms Melanotan II presence with excipients/fillers noted. HPLC chromatogram shows single dominant peak at 6.284 min retention time.

  • Batch information complete

    Lot number WL-ML10-P00518, BT Sample ID 005000040403800, labeled content 10 mg, actual potency 10.7 mg (107.3%), peptide-to-excipient ratio 1:4.3 within recommended range.

  • Dates valid

    Date tested 2026-06-08, issue date 2026-06-12. Both dates are on or before the authoritative current date of 2026-09-05 and show appropriate 4-day turnaround.

  • Lab information present

    BTLabs, 5730 Corporate Way Suite 220, West Palm Beach, FL 33407. Contact info and website provided. Dual scientist signatures (Andrea Castro AS, Verna Zheng AS). QR code present for verification.

  • Limited scope testing

    This COA explicitly states it does NOT provide information on particulate matter, microbial contamination, or presence of endotoxins. This is a purity/identity-focused report. Endotoxin, sterility, microbial, heavy metals, and residual solvent testing are not included in this document.

  • Professional presentation

    Report includes header/footer with report number IF-824-QSA-TR006-BTL2718-07, revision 1.0 January 2025, page numbering (1 of 2, 2 of 2), visual description of sample, FTIR spectrum, HPLC chromatogram with peak table, and USP method references.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.