Public COA audit

Buffered NAD+ · NAD+

Audited September 5, 2026

Consistent with a legitimate COA

Document structure and test panels align with what we expect from authentic lab reports.

Legitimacy
92
Confidence
93%
Panels
4/7
Purity (printed)
99.956%

Scored high because document structure and panels look consistent with authentic lab output and limited panel coverage (4/7). To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
NBD202601
Identity method
LC-MS
Sample date
2026-02-06
Issue date
2026-02-07

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

4 of 7 present · 4 passed · 0 failed · 0 reported · 3 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    NAD+

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.956%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    All negative (Pb, Cd, As, Hg)

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    PASS

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.956% purity by RP-HPLC with batch clarity results showing consistent purity across two vials (99.941% and 99.897%). High purity is normal for research-grade compounds.

  • Identity confirmed by LC-MS

    NAD+ identity confirmed by LC-MS matching reference standard.

  • Batch number present

    Batch NBD202601 clearly documented with molecular formula C21H27N7O14P2 and CAS 53-84-9.

  • Dates within normal range

    Received 02/06/2026, analyzed 02/07/2026. Both dates are on or before the current date (2026-09-05) and show appropriate turnaround time.

  • Lab identification present

    Kovera Labs identified with verification URL (koveralabs.com/verify), report number KVR-2026-727511, access code YNS8A76, and lab director signature.

  • Core panels present

    Document includes purity (RP-HPLC), identity (LC-MS), heavy metals screening, and endotoxin safety screen. Microbial, sterility, and residual solvent/water panels not included.

  • Endotoxin testing documented

    Endotoxin Safety Screen shows PASS result with specification ≤0.5 EU/mL.

  • Professional presentation

    Document includes chromatogram, batch clarity results for multiple vials, QR code for verification, and comprehensive formatting consistent with professional laboratory reporting.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.