Public COA audit
KPV
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 85%
- Panels
- 2/7
Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 3 soft concerns, and notable note: "Sterility-only report". To improve: include identity, purity, and endotoxin at minimum and prefer labs with a public verification portal.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- KV202606
- Sample date
- 2026-06-10
- Issue date
- 2026-06-10
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Not on this certificate file · core
Compound identity confirmed (e.g. HPLC, mass spec).
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Purity
Not on this certificate file · core
Reported purity percentage for the analyte.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Tested · passed
Bioburden / microbial limits testing.
Bacteria: No Growth; Fungi/Yeast: Not Detected
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Tested · passed
Sterility testing where applicable.
No microbial growth detected
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Sterility-only report
This is a sterility/microbial screening report only. No purity, identity, endotoxin, heavy metals, or residual solvent testing is included in this document. This appears to be a split report for lot KV202606.
Rapid screening method
Document explicitly states this is a rapid 2-day screening method suitable for quality control, not full USP <71> sterility testing. For regulatory compliance, full sterility testing may be required.
Lab verification not attempted
Kovera Labs is named as the testing facility. No URL or contact information provided for independent verification. QR code present but verification URL not extracted from image.
Clear lot identification
Lot number KV202606 clearly stated with report number KVR-2026-DD8FF8 and access code DD8FF8.
Same-day turnaround
Sample received and certified on same day (2026-06-10), consistent with rapid 2-day screening methodology.
Professional presentation
Document has professional layout with clear sections, branded header, and sample photo included.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.